HOME

 










Summary of Building Specifications

Number of floors 33
Typical wall to core wall distance 15 m (approx. 49 ft. 3 in.)
Curtain wall Solar reflective double-glazed insulating glass set in fluorocarbon coated aluminium frames
Mullion to mullion distance 1.4 m (approx. 4 ft. 7 in.)
Office floor headroom (From finished raised floor to finished suspended ceiling) 2.7 m (approx. 8 ft. 10 in.)
Raised floor clear void 120 mm (approx. 4.7 in.)
Trunking Three ceiling trunkings for power, telephone and ELV along corridor
Office floor loading 5kPa (110 lb per sq. ft.) plus 1.5kPa (33 lb per sq. ft.) allowance for office partitions
Inter-floor internal staircases provision Structurally feasible for installation of internal staircases at designated locations at tenants' cost
Passenger lifts Four air-conditioned lifts serving the floors in the low zone (7th-19th floors) with another four air-conditioned lifts serving the floors in the high zone (20th-31st floors) with AV display in DVD format displaying floor directories, financial news, world weather information, and other information upon request. One carpark passenger lift serving the basement floors and the retail podium
Service lift One 2,000 kg (approx. 4,400 lbs) service/fireman lift serving all floors of the building [Dimension (L)2.3 m x (D)1.7 m x (H)2.6 m]
After office hours access Card access control system to 2 designated lifts in high and low zone serving each office floor
Air-conditioning system Variable air volume (VAV) system with direct digital temperature control 24-hour chiller water supply for computer room cooling can be obtained at tenants' cost. Heating is provided to the area adjoining the external walls
Air-conditioning design cooling capacity Average of one person per 7 sq. m. (approx. 75 sq. ft.)
Open-plan lighting intensity level 500-600 lux average at desktop level
Electrical loading design parameter 120VA per sq. m. (approx. 11.15 VA per sq. ft.) average
Standby power supply provision 60Amp at 380 Volt 50 Hertz 3 phase for each office floor up to a maximum loading of 750 Amp from generator for tenants' essential applications
Telecommunication networks Advanced Fibre Telecom (AFT) System served by two digital electronic telephone exchanges coupled with optical fibre cables. 100 mm x 100 mm telephone trunking along the corridor of each office floor with tee offs to each tenant unit for tenants' wiring and connection. Inter-floor cable trunking is available for multi-floor tenants. Satellite antenna is set up to receive worldwide TV signals from AsiaSat-1 and Yuri A, B.
Car parking Over 100 indoor parking spaces with carbon monoxide monitoring system
Loading & unloading A spacious loading/unloading area with parking spaces for lorries and goods vehicles is provided at the G/F of the building
Internet Connectivity System An advanced high-speed high bandwidth IP Internet Connectivity System is provided for instant data transfer
Energy efficiency The Electrical & Mechanical Services Department of the HKSAR Government has certified Man Yee Building as an "Energy Efficient Building"
Excellent Environmental Management The Hong Kong Building Environmental Assessment Method has awarded Man Yee Building with the EXCELLENT GRADE in building design, operation, maintenance and management with regard to minimizing adverse effects on the global and local environments, whilst promoting a healthy indoor environment.

 

© 2004 Man Hing Hong. All Rights Reserved.